
Create: Networking
Kinetic network protection, contracts, limiters and compact fuses for Create.
Оцените первым
1.2K
13
Список изменений
Create: Networking 0.1.2 Beta Reliability Release Candidate 2
This update is the result of additional internal testing and focuses on kinetic correctness, Create compatibility, serial protection and capacity provenance.
Core fixes
- Removed the custom powered-Clutch override. Native Create Clutches now control their output normally, including when placed directly beside a Network Limiter.
- Increased loop confirmation time to reduce false loop detection while blocks and kinetic networks are still being placed or rebuilt.
- Normal provider outages no longer latch a Safety Breaker as a Supply Fault. The branch stops and resumes naturally with its source.
- Safety Breakers remain latched only for confirmed bypass loops or real output overloads.
- Removed automatic Safety-Breaker direction flipping during assignment.
Serial and parallel limiter handling
- Added conservative automatic recognition of a serial protection layout: provider -> standalone limiter -> Contract Anchor -> transfer limiter.
- Auto-detection only assigns a Safety Breaker when exactly one linked Contract Anchor exists downstream for several consecutive checks.
- Ambiguous layouts with multiple downstream contracts are left unchanged.
- Manual Safety Links through the Network Connector remain supported.
- A standalone limiter can forward native generator provenance through a serial chain.
- Capacity transferred through a Contract Anchor is marked non-forwardable, preventing imported SU from being exported again.
Capacity and loop correctness
- Local/native capacity is now tracked separately from imported contract capacity even across serial standalone limiters.
- Two networks with their own local generators may export simultaneously.
- Imported power alone cannot create exportable capacity.
- A closed limiter loop without real generation cannot sustain itself.
- Contract reservations remain attached to the provider side and are not duplicated by a serial Safety Breaker.
Visual fixes
- Enlarged and slightly protruded the static shaft in the inventory models for the Network Limiter, Contract Anchor and Compact Fuse.
- The item icons should now visibly show the integrated shaft.
Compatibility
- Minecraft 1.21.1
- NeoForge 21.1.x
- Create 6.0.x
Метаданные
Канал релиза
Beta
Номер версии
0.1.2-beta
Загрузчики
NeoForge
Версии игры
1.21.1
Загрузок
82
Дата публикации
16.07.2026
